New features in version 6.6.1 |
- Definition of the minimum period in milliseconds between two characters for RTU master instances
- Improvement of the TCP / IP connection stability
|
|
New features in version 6.5.1 |
- The slave ID can now be specified up to 255, previously a maximum of 247
- internal optimizations
|
|
New features in version 6.4.1 |
- get STRING datatype with byte order
- .net version only: new datatype SByte (signed byte)
- java version only: new datatype UByte (unsigned byte)
- Bugfix: optimized internal speed
|
|
New features in Version 6.3.1 |
- Bugfix: Internal performance settings
|
|
New features in Version 6.2.1 (only JAVA) |
- Additional enums eFlowcontrol "RTSCTS, XONXOFF und RTSCTS_XONXOFF"
|
|
New features in Version 6.1.2 |
- new Communication type RTU_over_TCP
- (only .NET) property Readtimeout is deprecated, please use property OperationTimeout instead
- (only .NET) property Connecttimeout is deprecated because of misspelling, please use property ConnectTimeout instead
- (only .NET) CRC / LCR check can be switched off on request for the Modbus master with new Property CRCCheckEnabled
- (only Java) function getReadtimeout() is deprecated, please use function getOperationTimeout() instead
- (only Java) method setReadtimeout() is deprecated, please use method setOperationTimeout() instead
- (only Java) function getConnecttimeout () is deprecated because of misspelling, please use function getConnectTimeout () instead
- (only Java) method setConnecttimeout () is deprecated because of misspelling, please use method setConnectTimeout () instead
- (only Java) CRC / LCR check can be switched off on request for the Modbus master with new method/function boolean getCRCCheckEnabled() and setCRCCheckEnabled(boolean value)
|
|
New features in Version 5.6.5 |
- Identification flag for related requests
|
|
New features in Version 5.6.0 |
- Bugfix: Reading single bits from holding register (collection)
|
|
New features in Version 5.5.0 |
- New function (Overwrite the auto-disconnect while Timeout)
|
|
New features in Version 5.4.1 |
- Parameter to limited the PDU length
|
|
(java version only) New features in Version 5.3.0 |
- Bugfix: Error reading more than 63 registers in a call
|
|
New features in Version 5.2.0 |
- Option to enable or disable diagnostic log
|
|
New features in Version 5.1.0 |
- Official support of "Encapsulated Interface transport" FC43 / MEI 13
- Internal improvements in terms of speed and stability
- Memory leak while bad connection (logging)
|
|
New features in Version 4.7.0 |
- Bugfix doubled error code -19
|
|
New features in Version 4.6.0(only JAVA) |
- Bugfix ReadCollections HoldingRegister from address 63
|
|
New features in Version 4.5.0(only JAVA) |
- Bugfix Read/Write of floats and doubles
- Bugfix ReadrequestBuilder from Address 32
|
|
New features in Version 4.4.0 |
- memory delete when reading a read collection
|
|
New features in Version 4.3.5 |
- from this version compatible to JRE7 and JRE8
|
|
New features in Version 4.1.0 |
- internal optimization for a faster access
- Bug fix while reading bytes for „showing wrong address“
|
|
New features in Version 3.3.3 |
- Bug fix for DNS and IPV6 problems
|
|
New features in Version 3.3.2 |
- Bug fix, Errormessage while fast calls at Modbus-Slave
|
|
New features in Version 3.2.1 |
- Bug fix, Sequence-Error at telegram 256 in Modbus-Slave
|
|